Noise control for cooling fans on heavy vehicles
In this paper two different objects for fan passive noise control have been examined: heat exchangers and inlet/outlet parallel splitter silencers based on micro-perforated panels. The first object is theoretically and experimentally examined while the second is only examined experimentally.
Throughout this paper two measurement methods were used. The ISO 15186-1:2000 to test the acoustic transmission for a diffuse field and plane wave testing in a duct of a sample cut from each heat exchanger type. Based on an anisotropic equivalent fluid model a theoretical model for the heat
exchanger acoustic transmission is presented. A new type of splitter silencers based on micro-perforated plates, which can add damping up 10-20 dB in the frequency range of interest (<5 kHz), are also presented.
Document Type: Research Article
Affiliations: KTH
Publication date: 01 November 2012
NCEJ is the pre-eminent academic journal of noise control. It is the Journal of the Institute of Noise Control Engineering of the USA. Since 1973 NCEJ has served as the primary source for noise control researchers, students, and consultants.
- Information for Authors
- Submit a Paper
- Subscribe to this Title
- Membership Information
- INCE Subject Classification
- Ingenta Connect is not responsible for the content or availability of external websites
- Access Key
- Free content
- Partial Free content
- New content
- Open access content
- Partial Open access content
- Subscribed content
- Partial Subscribed content
- Free trial content