Case study of simplified reverberation time measurement under multiple conditions using a sound level meter
Recent advancements in the computational capacity of sound level meters have facilitated the simultaneous recording of diverse calculation results and waveform recording data. Traditionally, reverberation time determination entailed manually adjusting a linear regression line to the
reverberation decay curve derived from recorded sound levels, followed by reverberation time computation based on the gradient of said line. However, automated techniques have made reverberation time calculation via a sound level meter feasible. This paper discusses a case study evaluating
the efficacy and considerations of simplified reverberation time measurements conducted across various conditions, encompassing scenarios with multiple sound sources and diverse indoor environments. The study leveraged recorded data from a sound level meter and employed automated methods simulated
on a personal computer.
The requested document is freely available to subscribers. Users without a subscription can purchase this article.
- Sign in below if you have already registered for online access
Sign in
Document Type: Research Article
Affiliations: RION CO., LTD.
Publication date: 04 October 2024
The Noise-Con conference proceedings are sponsored by INCE/USA and the Inter-Noise proceedings by I-INCE. NOVEM (Noise and Vibration Emerging Methods) conference proceedings are included. All NoiseCon Proceedings one year or older are free to download. InterNoise proceedings from outside the USA older than 10 years are free to download. Others are free to INCE/USA members and member societies of I-INCE.
- Membership Information
- INCE Subject Classification
- Ingenta Connect is not responsible for the content or availability of external websites
- Access Key
- Free content
- Partial Free content
- New content
- Open access content
- Partial Open access content
- Subscribed content
- Partial Subscribed content
- Free trial content