Optical interferometry implementation considerations for sinusoidal low frequency accelerometer measurements and calibrations

Buy Article:

$15.00 + tax (Refund Policy)

Vibration metrology utilizing sine excitation stimulus, based either on fringe counting or minimum point methods, employs Michelson interferometers for the calibration of accelerometers. The former method combines the optical reference and measurements arms from a static mirror and reflected by the accelerometer respectively which are then directed to a suitable photodiode for processing. The stroking motion due to the oscillation of the accelerometer will contribute to the misalignment of the two optical paths and there are three methods to compensate for this. The first requires the mounting of a mirror on the accelerometer itself and the effect of the added mass from the mirror can be accounted for and corrected. The second requires the mounting of three mirrors on the mounting surface of the accelerometer but this requires the alignment of the Michelson interferometer for each mirror. The third is to use two retro reflectors so that the returning measurement beams are always along the same path with the reference; however, this requires the alignment of the interferometer for each retro-reflector. This paper will discuss such considerations on the optical systems, their components and associated instrumentation and discuss the design of an alternative approach that can overcome certain limitations.

The requested document is freely available to subscribers. Users without a subscription can purchase this article.

Sign in

Document Type: Research Article

Affiliations: 1: National Research Council Canada 2: National Research Council Canada, Metrology Research Centre 3: University of Ottawa, Department of Mechanical Engineering

Publication date: 04 October 2024

More about this publication?
  • The Noise-Con conference proceedings are sponsored by INCE/USA and the Inter-Noise proceedings by I-INCE. NOVEM (Noise and Vibration Emerging Methods) conference proceedings are included. All NoiseCon Proceedings one year or older are free to download. InterNoise proceedings from outside the USA older than 10 years are free to download. Others are free to INCE/USA members and member societies of I-INCE.

  • Membership Information
  • INCE Subject Classification
  • Ingenta Connect is not responsible for the content or availability of external websites
  • Access Key
  • Free content
  • Partial Free content
  • New content
  • Open access content
  • Partial Open access content
  • Subscribed content
  • Partial Subscribed content
  • Free trial content