Measurement uncertainty of ISO CD 23351-2 - Preliminary results
The purpose of our study was to determine the measurement uncertainty of ISO CD 23351-2 draft standard. Two sub-studies were conducted. In study 1, an accuracy experiment was conducted where 7 participants tested in the same room (in situ) two different products (full enclosure and
partial enclosure). In study 2, an experiment was conducted where a single participant tested two different products in several rooms varying in room volume and reverberation time. Study 1 yielded an in-situ reproducibility standard deviation of 0.80.9 dB. Study 2 yielded a between-site standard
deviation of 0.7 dB. The small standard deviations suggest that the technical content should not be essentially changed in the next versions of the standard. The results could be considered in next version of the standard ISO DIS 23351-2.
The requested document is freely available to subscribers. Users without a subscription can purchase this article.
- Sign in below if you have already registered for online access
Sign in
Document Type: Research Article
Affiliations: 1: Turku University of Applied Sciences 2: Politecnico di Torino
Publication date: 04 October 2024
The Noise-Con conference proceedings are sponsored by INCE/USA and the Inter-Noise proceedings by I-INCE. NOVEM (Noise and Vibration Emerging Methods) conference proceedings are included. All NoiseCon Proceedings one year or older are free to download. InterNoise proceedings from outside the USA older than 10 years are free to download. Others are free to INCE/USA members and member societies of I-INCE.
- Membership Information
- INCE Subject Classification
- Ingenta Connect is not responsible for the content or availability of external websites
- Access Key
- Free content
- Partial Free content
- New content
- Open access content
- Partial Open access content
- Subscribed content
- Partial Subscribed content
- Free trial content