Outdoor Concert Hotel Acoustics
VAI Resort, situated across the street from the site of Super Bowl LVII, presents a number of acoustical challenges, not the least of which is a world-class, 360-degree outdoor performance venue. Performers will blast an 8-storey hotel located 250 ft away with music of all types, which
audiences will enjoy from the balconies of their hotel rooms. The challenge of modeling such a venue comes in simplifying it down to manageable pieces. Does a balcony with a hotel room behind it behave like a Helmholtz resonator? How do the acoustics change if 90% of the balconies are open
to the hotel rooms beyond? What if 50% are open? 25% are open? Such a variable acoustic space presents a significant modeling challenge. A methodology for tackling such a large-scale project is presented, with modeling results, auralizations, and comparisons to real-world measurements. Findings
include a swing in RT60 of more than 25% when all balcony doors are opened versus closed.
Document Type: Research Article
Affiliations: 1: MD Acoustics LLC 2: MD Acoustics, LLC
Publication date: 25 May 2023
The Noise-Con conference proceedings are sponsored by INCE/USA and the Inter-Noise proceedings by I-INCE. NOVEM (Noise and Vibration Emerging Methods) conference proceedings are included. All NoiseCon Proceedings one year or older are free to download. InterNoise proceedings from outside the USA older than 10 years are free to download. Others are free to INCE/USA members and member societies of I-INCE.
- Membership Information
- INCE Subject Classification
- Ingenta Connect is not responsible for the content or availability of external websites
- Access Key
- Free content
- Partial Free content
- New content
- Open access content
- Partial Open access content
- Subscribed content
- Partial Subscribed content
- Free trial content