Industrial fan vibration signature characterization
Technique for measuring and reducing industrial fan vibration and noise is detailed. A method used to characterize the vibration signature for 100% industrial fan systems shipped is described. A fan system consists of motor, propeller and cage. We measure triax accelerometer vibration,
microphone (both sound pressure level in dBA and raw signal in Pa) along with the current of three phase power for each fan shipped. Comparisons are done immediately with the ISO 14694:2003 standard and troubleshooting and design changes are implemented if vibration limits are exceeded. The
method and results are provided for several cases. Troubleshooting and best practices are described for various designs. A portable system takes measurements in the field which are compared to the factory baseline characterization in real time to solve installation problems.
Document Type: Research Article
Publication date: 01 August 2021
The Noise-Con conference proceedings are sponsored by INCE/USA and the Inter-Noise proceedings by I-INCE. NOVEM (Noise and Vibration Emerging Methods) conference proceedings are included. All NoiseCon Proceedings one year or older are free to download. InterNoise proceedings from outside the USA older than 10 years are free to download. Others are free to INCE/USA members and member societies of I-INCE.