Application of CLD for reduction of structure-borne noise in electronic enclosures
Large clusters of electronic equipment inside enclosures could generate structural vibrations and radiated noise. Depending on the location of an electronic enclosure, the internally generated vibrations and noise may be transmitted to the outside environment and create secondary problems.
A customized constrained layer damper (CLD) solution was investigated for reducing structural vibrations and structure-borne noise. The elastomeric element of the CLD is based on a modified formula suitable for room temperature applications. A metal plate was used to represent an electronic
enclosure wall. Vibrating metal plates with and without the application of CLD are evaluated. It is demonstrated that the metal plate with CLD showed 8 – 25 dB reduction of noise in the frequency range of 60 Hz to 1000 Hz. Results from the CLD tests are presented along with further considerations
of CLD for application to electronic enclosures.
Document Type: Research Article
Affiliations: ShockTech
Publication date: 12 October 2020
The Noise-Con conference proceedings are sponsored by INCE/USA and the Inter-Noise proceedings by I-INCE. NOVEM (Noise and Vibration Emerging Methods) conference proceedings are included. All NoiseCon Proceedings one year or older are free to download. InterNoise proceedings from outside the USA older than 10 years are free to download. Others are free to INCE/USA members and member societies of I-INCE.
- Membership Information
- INCE Subject Classification
- Ingenta Connect is not responsible for the content or availability of external websites
- Access Key
- Free content
- Partial Free content
- New content
- Open access content
- Partial Open access content
- Subscribed content
- Partial Subscribed content
- Free trial content