Predicting Light-Rail Groundborne Noise and Vibration from Tunnels
The standard measurement procedure for vibration propagation measurements for subway testing is borehole testing prior to the construction of the subway tunnel. Borehole testing is completed by drilling a borehole to the depth of the subway and locating a force transducer at the bottom
of a hole. Typically, a standard soil sampling hammer is used to impact the transducer and excite the ground at the bottom of the hole. However, this measurement procedure does not account for the attenuation provided by the tunnel structure and may result in the overprediction of vibration
and groundborne noise levels. This paper looks at some measured vibration propagation data from boreholes and from inside a constructed subway tunnel along the same alignment, as well as numerical models to estimate the attenuation from the tunnel structure. The results indicate that the tunnel
structure likely provides between 5 to 10 decibels of vibration reduction at frequencies above 40 Hz.
Document Type: Research Article
Affiliations: ATS Consulting
Publication date: 18 December 2018
The Noise-Con conference proceedings are sponsored by INCE/USA and the Inter-Noise proceedings by I-INCE. NOVEM (Noise and Vibration Emerging Methods) conference proceedings are included. All NoiseCon Proceedings one year or older are free to download. InterNoise proceedings from outside the USA older than 10 years are free to download. Others are free to INCE/USA members and member societies of I-INCE.
- Membership Information
- INCE Subject Classification
- Ingenta Connect is not responsible for the content or availability of external websites
- Access Key
- Free content
- Partial Free content
- New content
- Open access content
- Partial Open access content
- Subscribed content
- Partial Subscribed content
- Free trial content