Comparison of acoustic emission signals generated by high voltage current transformer insulation system

Buy Article:

$15.00 + tax (Refund Policy)

Exemplary measurement results of acoustics emission (AE) signals generated by partial discharges (PD) occurring in high voltage current transformer (HVCT) internal insulation system are presented in the paper. High voltage current transformers are commonly used apparatus in electrical power distribution systems. HVCT insulation system design is quite complex. High voltage and grounded parts are separated by porcelain insulation. Inside of the porcelain there are windings covered with an oil paper insulation, furthermore a proper electric field distribution is provided by some additionally mounted electrodes. Due to insulation system ageing process some degradation of dielectrics may occur which usually leads to local partial discharge generation. Various combustible gasses production is accompanied by PD generation as well as a significant pressure increase may also be noticed inside of a HVCT. In some exceptional circumstances an internal pressure may exceed a critical value and a porcelain insulator may explode thus a fire of the entire insulation system is also possible Presented measurements are proceeded on the J110-4a type HVCT with nominal voltage of 110 kV, wherein an internal insulation system fault is detected. Indication of AE signals occurring inside of a HVCT potential application possibilities for insulation fault detection and localization are the main purpose of the presented research. Three different piezoelectric joint AE sensors, with different response characteristics are applied for the research. Various voltage supply levels are investigated in order to every sensor sensitivity threshold to be assigned. Exemplary representative AE signals generated inside of the HVCT are registered for selected supply voltage levels. Fundamental time, frequency and time-frequency domain descriptors are applied for AE signals further analysis. According to conducted comparative analysis results an optimal AE sensor for on-site measurements on apparatus under normal operation conditions is pointed.

The requested document is freely available to subscribers. Users without a subscription can purchase this article.

Sign in

Document Type: Research Article

Affiliations: Opole University of Technology, Poland

Publication date: 07 December 2017

More about this publication?
  • The Noise-Con conference proceedings are sponsored by INCE/USA and the Inter-Noise proceedings by I-INCE. NOVEM (Noise and Vibration Emerging Methods) conference proceedings are included. All NoiseCon Proceedings one year or older are free to download. InterNoise proceedings from outside the USA older than 10 years are free to download. Others are free to INCE/USA members and member societies of I-INCE.

  • Membership Information
  • INCE Subject Classification
  • Ingenta Connect is not responsible for the content or availability of external websites
  • Access Key
  • Free content
  • Partial Free content
  • New content
  • Open access content
  • Partial Open access content
  • Subscribed content
  • Partial Subscribed content
  • Free trial content